首页> 外文会议>SPIE Conference on Optical Modeling and Performance Predictions >Spatial and spectral sampling analysis of the spectral imaging system based on the light-field architecture
【24h】

Spatial and spectral sampling analysis of the spectral imaging system based on the light-field architecture

机译:基于灯场架构的光谱成像系统的空间和光谱采样分析

获取原文

摘要

The light filed modulated imaging spectrometer (LFMIS) can obtain a multispectral data cube in a single shot. The spatial sampling is effected by the design of spectral filters, because the diffraction limit increases as the sizes of the filters decrease. The spatial and spectral sampling characters of the system are determined by the system parameters, specially the parameters of the filters. This research presents the models of the system and the linear-variable optical filters (LVFs). The spatial sampling character is analyzed theoretically and confirmed by simulation results. Simulation experiments are performed to analyzed the characters of LVFs that effect the spectral sampling character. The results provide the parameter requirements of LVFs when designing an LFMIS system based on LVFs.
机译:光归档调制成像光谱仪(LFMI)可以在单次拍摄中获得多光谱数据立方体。空间采样由光谱滤波器的设计实现,因为随着滤波器的尺寸减小,衍射限制增加。系统的空间和光谱采样字符由系统参数确定,特别是滤波器的参数。本研究介绍了系统的模型和线性可变光学滤波器(LVF)。理论上分析空间采样特征,并通过模拟结果证实。进行仿真实验,分析了影响光谱采样特征的LVF的特征。结果为基于LVFS设计LFMIS系统时,提供了LVF的参数要求。