This paper is a synthesis of the results of several studies conducted by CETIAT on microchannel heat exchangers. Performance of microchannel heat exchangers in evaporation and condensation were measured leading in both modes to higher capacities and lower air side pressure drops compared to those of conventional finned tube coils. Considering the good behaviour of the microchannel heat exchanger, it was decided to study the integration of a microchannel heat exchanger in a reversible heat pump. The objectives were to evaluate the performance, the reduction of refrigerant charge and the overall dimensions of the heat pump being equipped with the microchannel heat exchanger and the original finned tube coil. Results show a reduction in refrigerant charge of about 40 to 50% for a 8 kW output unit, leading to a ratio of charge of 110 g/kW and a reduction in the overall dimensions of the heat pump of 20%, for similar or greater output capacities.
机译:本文是通过CETIAT对微通道热交换器进行的几项研究的结果的合成。微通道热交换器在蒸发和冷凝中的性能,以与传统的翅片管线线圈相比,两种模式以更高的容量和更低的空气侧压降。考虑到微通道热交换器的良好行为,决定研究微通道换热器在可逆热泵中的集成。目的是评估性能,制冷剂的减少和热泵的整体尺寸配备有微通道换热器和原始翅片管线线圈。结果显示为8 kW输出单元的制冷剂电荷的降低约为40%至50%,导致110g / kW的电荷比率和热泵总体尺寸的减少,相似或更大输出容量。