首页> 外文会议>International Exhibition Conference for Power Electronics Intelligent Motion Power Quality >Effect of overlap on Medium Voltage High Power High Frequency Transformers
【24h】

Effect of overlap on Medium Voltage High Power High Frequency Transformers

机译:重叠对中电压高功率高频变压器的影响

获取原文

摘要

This paper presents the effect of leakage inductance of Medium Voltage High Power High Frequency Transformers for Direct Current Transmission and Distribution systems on offshore wind farms on current waveforms, output voltage and control. Simulation and experimental results on a 1 kW prototype with a three phase toroidal tape-wound core transformer made of nanocrystalline material are presented.
机译:本文介绍了中电压高功率高频变压器漏电电感的影响,在海上风电场上直流传输和分配系统对电流波形,输出电压和控制。提出了用纳米晶体材料制成的三相环形带卷绕芯变压器的1kW原型上的仿真和实验结果。