首页> 外文会议>International Conference on Life System Modeling and Simulation >Validation of Veracity on Simulating the Indoor Temperature in PCM Light Weight Building by EnergyPlus
【24h】

Validation of Veracity on Simulating the Indoor Temperature in PCM Light Weight Building by EnergyPlus

机译:验证通过EnergyPlus模拟PCM轻量级建设中室内温度的准确性

获取原文

摘要

This article surveys the EnergyPlus constructions solution algorithm and heat balance method in EnergyPlus, presents the new conduction finite difference solution algorithm and enthalpy-temperature function features, describes the implementation of the module, and validates the veracity of the possible applications for the capabilities in EnergyPlus by PCM experiment dates. The most relativity difference is 12.41% and the least is 0.71% between the simulation and testing value in sequential 36h on the A envelope condition, wheras on the B envelope condition the most relativity difference is 8.33% and the least is 0.33% in sequential 72h. The results to date has shown good agreement with well established in this simulation tools and shown that the algorithm incorporated into EnergyPlus can simulate the PCM in building construction.
机译:该文章调查了LeftenceLus中的能量保护解决方案解决方案算法和热平衡方法,介绍了新的传导有限差分解决方案算法和焓 - 温度函数特征,描述了模块的实现,并验证了可能的应用程序中可能的应用程序的真实性通过PCM实验日期。最相对论的差异为12.41%,并且在包络条件下,仿真和测试值之间的模拟和测试值之间最小值为0.71%,在包络条件下,最相对论的差异为8.33%,序列72h中最少的0.33% 。迄今为止的结果表明,在该仿真工具中建立了良好的一致性,并表明该算法包含在EnergyPlus中可以模拟建筑结构中的PCM。