A mixture of Al_2O_3 and pure-Al powder was successfully deposited on weld nugget of the spot weld dissimilar metals Mg and galvanized steel. The cross-sectional microstructure was analyzed using SEM. Also, residual stress was measured through hole drilling and X-ray diffraction methods. The obtained microstructure analysis shows that mixture of Al and Fe with a continuous layer of ~2.7 μm were observed at the interface of weld nugget/coat. At the same time, equiaxed grains were observed near the interface. In contrast, the Zn containing interlayer thickness of ~14 μm with porosity was identified at the interface of the coating on the Zn coated steel. The hardness distribution also revealed that the interface obtained lower hardness compared to the substrate and coating. At the same time, the residual stress also changes through thickness of the coating to the substrate which will improve the corrosion and fatigue properties.
机译:Al_2O_3和纯-Al粉末的混合物成功地沉积在点焊接焊接不同金属Mg和镀锌钢的焊缝中。使用SEM分析横截面微观结构。此外,通过孔钻孔和X射线衍射方法测量残余应力。所获得的微观结构分析表明,在焊缝/涂层的界面处观察到Al和Fe的混合物〜2.7μm的连续层。同时,在界面附近观察等轴晶粒。相反,在Zn涂层钢上的涂层的界面处鉴定含有孔隙率的含层厚度〜14μm的Zn。硬度分布还显示与基材和涂层相比,界面获得了较低的硬度。同时,残余应力也通过涂层的厚度改变为基材,这将改善腐蚀和疲劳性能。