【24h】

SSC Resistance of QT-900 Coiled Tubing

机译:QT-900卷绕管的SSC电阻

获取原文

摘要

Laboratory sulfide stress cracking (SSC) tests were performed on specimens taken from a QT-900 coiled-tubing test string in an attempt to define zones of acceptable sour service. SSC tests were performed at room temperature in brine fluid environments with H_2S partial pressures (P_(H_2S)) ranging from 0.01 to 10 bars and pH levels from 2.8 to 4.5. In addition, the effectiveness of a new inhibitor for crack prevention was tested. SSC testing, which included NACE Method A tensile, four-point bent beam and slow strain rate test specimens, were performed on as-milled as well as fatigue-cycled tubing. Fatigue cycling of the QT-900 test string was performed on a pressure bending fatigue machine with tubing samples cycled from 33% to 75% of average tested fatigue life. Test specimens were taken from parent metal, bias weld, seam weld (ERW), and butt weld locations. As a result of this test program, acceptable zones of service in sour environments have been proposed although further testing may alter boundary locations.
机译:在从QT-900卷绕管试验串所采取的试样上进行实验室硫化物应力裂化(SSC)测试,以试图定义可接受的酸维修的区域。 SSC测试在室温下在盐水流体环境中进行,其中具有H_2S的部分压力(P_(H_2S)),范围为0.01至10巴,pH水平为2.8至4.5。此外,测试了新抑制剂对裂纹预防的有效性。包括NACE方法的SSC检测是在AS-MROODED以及疲劳循环的管道上进行拉伸,四点弯曲梁和慢菌速率试样的拉伸率。 QT-900测试串的疲劳循环在压力弯曲疲劳机上进行,管样品循环从平均经过的平均经过的疲劳寿命的33%至75%。试样从母金属,偏置焊接,煤层焊接(ERW)和对接焊接位置取出。由于该测试程序,已经提出了酸环境中可接受的服务区域,尽管进一步测试可能改变边界位置。