摘要

The use of electromagnetic techniques for the inspection and determination of distress (broken wires) for Prestressed Concrete Cylinder Pipe (PCCP) has greatly increased over the past 7 years. There are two primary providers of these services that use generically similar methods. Individually the results from each provider have been investigated with mixed results. Direct comparison of results between the two providers and confirmation of the results by excavation had not been performed before. As part of an AWWA Research Foundation study (Romer, 2004), comparisons of the results between the two electromagnetic inspection providers were made on several PCCP pipelines. Correlation between the two electromagnetic inspection results was modest. However, excavation for direct physical examination of the pipes to verify the predicted distress, or lack of distress, was not possible at the time of the electromagnetic inspections. The opportunity to directly compare and confirm the accuracy of inferred prestressing wire damage was finally possible on one of the San Diego County Water Authority's (Water Authority) pipelines. Both providers of electromagnetic inspection services had surveyed the same segment of the pipeline with differing results. Direct comparison of electromagnetic results with actual observed distress has been determined at several locations. This paper reviews the results and documents the predicted electromagnetic results along with the observed physical condition of the pipe sections and emphasizes the importance of proper records and the utilization of other impact factors that affect the performance.
机译:在过去7年中,对预应力混凝土气缸管(PCCP)进行检查和测定的电磁技术(PCCP)的使用大大增加。这些服务有两个主要提供者,使用普遍上类似的方法。单独调查每个提供商的结果,并进行了混合结果。之前,直接比较了两种提供商与挖掘结果的确认结果。作为AWWA研究基金会研究的一部分(ROMER,2004),在几个PCCP管道上进行了两种电磁检查提供商之间的结果比较。两个电磁检查结果之间的相关性谦虚。然而,在电磁检查时,不可能挖掘用于验证预测的遇险或缺乏痛苦的管道的直接体检。在圣地亚哥水务局(水当局)管道之一,最终可能直接比较和确认推断预应力线损坏的准确性。两家电磁检验服务提供商都调查了与不同结果不同的管道段。在若干地点确定了使用实际观察遇险的电磁结果的直接比较。本文审查了预测电磁结果的结果,以及管道部分的观察到的物理状况,并强调了适当的记录和影响性能的其他影响因素的重要性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号