首页> 外文会议>Conference on Optomechatronic Sensors and Instrumentation >Multipath interference test method for distributed amplifiers
【24h】

Multipath interference test method for distributed amplifiers

机译:分布式放大器的多径干扰测试方法

获取原文

摘要

A method for testing distributed amplifiers is presented; the multipath interference (MPI) is detected as a beat spectrum between the multipath signal and the direct signal using a binary frequency shifted keying (FSK) test signal. The lightwave source is composed of a DFB-LD that is directly modulated by a pulse stream passing through an equalizer, and emits the FSK signal of the frequency deviation of about 430MHz at repetition rate of 80-100 kHz. The receiver consists of a photo-diode and an electrical spectrum analyzer (ESA). The base-band power spectrum peak appeared at the frequency of the FSK frequency deviation can be converted to amount of MPI using a calibration chart. The test method has improved the minimum detectable MPI as low as -70 dB, compared to that of -50 dB of the conventional test method. The detailed design and performance of the proposed method are discussed, including the MPI simulator for calibration procedure, computer simulations for evaluating the error caused by the FSK repetition rate and the fiber length under test and experiments on singlemode fibers and distributed Raman amplifier.
机译:提出了一种用于测试分布式放大器的方法;使用二进制频率移位键控(FSK)测试信号,在多径信号和直接信号之间被检测为多径干扰(MPI)作为节拍频谱。光波源由DFB-LD组成,该DFB-LD由通过均衡器的脉冲流直接调制,并且在80-100kHz的重复率下发射大约430MHz的频率偏差的FSK信号。接收器包括光电二极管和电谱分析仪(ESA)。在FSK频率偏差的频率下出现的基带功率谱峰值可以使用校准图转换为MPI的量。与传统测试方法的-50 dB相比,测试方法改善了低至-70dB的最小可检测MPI。讨论了所提出的方法的详细设计和性能,包括用于校准程序的MPI模拟器,用于评估由FSK重复率和纤维长度引起的误差和在单模纤维和分布式拉曼放大器上进行的纤维长度来评估误差的计算机模拟。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号