首页> 外文会议>Annual IEEE INDICON >Root Cause Analysis of Commutator Damage in a 130 kW DC Recoiler Motor Drive
【24h】

Root Cause Analysis of Commutator Damage in a 130 kW DC Recoiler Motor Drive

机译:130千瓦直流辐射电机驱动中换向器损坏的根本原因分析

获取原文

摘要

A recent failure incident of a 130 kW DC Recoiler Motor Drive of a slitter machine involved complete, irrepairable damage to its commutator, whereby all the commutator segments were thrown out, causing some damage to roof coverings; luckily, it was a "No-Injury" accident. This accident occurred during the "auto-tuning" test part of the recommissioning with a brand new Digital Control Panel in place of a pre-existing Analogue Control Panel of late 1970 vintage, the dc motor remaining unchanged. A short summary of the results of the study carried out by the author for root cause analysis of this failure and prevention of such failures in future is presented in this paper
机译:最近的130千瓦直流辐射电机电机驱动器的最新故障涉及其换向器的完整,换向器损坏,从而抛出所有换向器段,导致屋顶覆盖物造成一些损坏;幸运的是,这是一个“无伤害”的事故。这次事故发生在“自动调整”测试部分,使用全新的数字控制面板的推荐,代替1970年代后期的复古预先存在的模拟控制面板,DC电机保持不变。本文介绍了由作者对该故障和预防此类失败进行此类故障和预防此类故障的研究结果的简短摘要