首页> 外文会议>Cryogenic Engineering Conference >Influence of hot end heat exchangers on cascading three pulse tube coolers
【24h】

Influence of hot end heat exchangers on cascading three pulse tube coolers

机译:热端换热器对三个脉冲管冷却器的影响

获取原文

摘要

Hot end heat exchanger (HHX), an indispensable part in the traditional pulse tube cooler (PTC), rejects the heat generated by dissipation of the acoustic power. The acoustic power, which should have been dissipated at the phase shifters, is delivered to the latter stage cooler in the cascade PTC. Therefore, by removing the HHX, power loss could be decreased. Specifically, in our experiment, after removing HHXs, the cooling power obtained by cascading three PTCs could reach 273.2 W at 233 K under the same working condition, which is 23.6 W more than that of the original structure.
机译:热端换热器(HHX),传统脉冲管冷却器(PTC)中不可或缺的部分,拒绝通过耗散声功率产生的热量。 应该在相移器处消散的声功率被输送到级联PTC中的后级冷却器。 因此,通过去除HHX,可以降低功率损耗。 具体地,在我们的实验中,在去除HHXS后,通过级联三种PTC获得的冷却功率在233 k下可以在相同的工作条件下达到273.2W,这比原始结构的23.6W更多。