首页> 外文会议>CIGRE Session >ELECTRICAL PERFORMANCE OF 10kV POLYMER INSULATOR UNDER LIGHTNING INDUCED VOLTAGE CONDITION
【24h】

ELECTRICAL PERFORMANCE OF 10kV POLYMER INSULATOR UNDER LIGHTNING INDUCED VOLTAGE CONDITION

机译:雷电诱导电压下10kV聚合物绝缘子的电气性能

获取原文

摘要

Protection of medium voltage (MV) overhead lines against indirect effects of lightning is an important issue in Malaysia and tropical countries. In order to consider on the protection of MV line versus indirect effects of lightning, the electrical performance of a 10kV polymer insulator under different conditions for impulse, weather and insulator angle with respect to cross-arm were studied in this paper (both experimental and simulation) and the results were discussed accordingly. The results show that the weather and also insulator angle (with respect to cross-arm) are strongly affected on the values of breakdown voltage and leakage current in both negative and positive impulses. Therefore, in order to set a proper protection system on the MV lines against lightning induced voltage, consideration on the local information such as on weather, insulator angles with respect to cross-arm and other line parameters can be helpful in obtaining good results and thus to increase line's lightning performance.
机译:保护中电压(MV)对闪电间接影响的高压(MV)架空线是马来西亚和热带国家的一个重要问题。为了考虑保护MV线与雷电间接影响,在本文中研究了不同条件下的10kV聚合物绝缘体的电气性能(关于横臂的不同条件)(实验和仿真) )相应讨论结果。结果表明,天气和绝缘角(相对于跨臂)对阴性和正脉冲中的击穿电压和漏电流的值强烈影响。因此,为了在MV线路上设定适当的保护系统免受雷电感应电压的,对诸如天气之类的局部信息的考虑,相对于跨臂和其他线参数的绝缘体角度可以有助于获得良好的结果,从而有用增加线路的闪电性能。