首页> 外文会议>Audio Engineering Society Convention >Analysis on Error Caused by Multi-scattering of Multiple Sound Sources in HRTF Measurement
【24h】

Analysis on Error Caused by Multi-scattering of Multiple Sound Sources in HRTF Measurement

机译:HRTF测量中多散射多散射引起的误差分析

获取原文

摘要

A model consisting of two pulsating spherical sound sources and a rigid-spherical head is proposed to evaluate the error caused by multi-scattering of multiple sound sources in HRTF measurement. The results indicate that the ipsilateral error below 20 kHz caused by multi-scattering is within ± 1 dB when the radius of sound sources does not exceed 0.025 m, the source distance to head center is not less than 0.5 m, and the angular interval between the two adjacent sources is not less than 25 degree. This accuracy basically satisfies the requirement of ipsilateral HRTF measurements. For improving the accuracy in contra lateral HRTF measurement, some sound absorption treatments on the source surface are necessary.
机译:提出了一种由两个脉动球形声源和刚性球形头组成的模型,以评估由HRTF测量中多次声源的多散射引起的误差。结果表明,当声源半径不超过0.025μm时,多散射引起的20kHz的同侧误差低于20kHz,在0.025米,与头部中心的源距不小于0.5米,并且之间的角间隔两个相邻的来源不小于25度。这种准确性基本上满足了同侧HRTF测量的要求。为了提高对抗横向HRTF测量的精度,需要在源表面上进行一些吸收处理。