【24h】

USE OF STRAIN GAUGED REBARS IN BLAST RESEARCH

机译:在爆炸研究中使用应变测量钢筋

获取原文

摘要

This paper describes the use of internally strain gauged reinforcing bars during blast tests on reinforced concrete slab panels conducted at the Southwest Research Institute (SwRI) in San Antonio, Texas. The challenge was to produce gauged bars that could withstand the violent strain peaks induced by blast effects. Seven bars were manufactured at the University of Durham and shipped to SwRI for installation in the test specimens. Some additional bars were also externally strain gauged using surface mounted strain gauges to permit a direct comparison of the two techniques. The externally mounted gauges performed erratically as a result of the blast effects. Some physically failed at the gauge/bar interface while others partially failed, yielding offsets in strain data. The internally gauged bars, however, performed very satisfactorily and proved themselves capable of recording the very high and transient peak stains (up to 30 000 microstrain in less than 1 millisecond) resulting from the blasts.
机译:本文介绍了在德克萨斯州圣安克萨斯圣安克萨斯(SWRI)在西南研究所(SWRI)进行的钢筋混凝土板块爆破试验中使用内部应变测量加强杆。挑战是生产可能承受爆炸效应诱导的剧烈应变峰的测量条。七条酒吧在达勒姆大学制造,并运往SWRI进行试验标本。使用表面安装应变仪的一些额外的杆也被外部应变,以允许直接比较这两种技术。由于爆炸效应,外部安装的仪表不规律地执行。在仪表/栏接口处有些物理上失败,而其他物体部分失败,则在应变数据中产生偏移。内部衡量条,但是,表现非常令人满意,并证明自己能够(在少于1毫秒到30微应变000)记录的非常高的和瞬时峰污渍从爆炸产生的。