首页> 外文会议>Corrosion Conference >LABORATORY AND FIELD CORROSION TESTS OF SURFACE-MODIFIED T22 STEEL IN WASTE INCINERATORS
【24h】

LABORATORY AND FIELD CORROSION TESTS OF SURFACE-MODIFIED T22 STEEL IN WASTE INCINERATORS

机译:废物焚烧炉中表面改性T22钢的实验室和野外腐蚀试验

获取原文

摘要

The corrosion resistance of surface-modified T22 steel for use as superheater tubes in waste incinerators was evaluated by laboratory and field corrosion tests. The specimen surface was coated with a Ni-30at. percent Cr-15at. percent Al film approximately 10pm thick by unbalanced-magnetron (UBM) sputtering, and then preoxidized for 12h at 1000 deg C in dry laboratory air. Laboratory corrosion testing was conducted by coating with synthetic ash in a gas mixture of 1000ppmHCl-50ppmSO_2-10 percent O_2-10 percent CO_2- 20 percent H_2O-bal centre dot N_2 for 100h at 550 deg C. The preoxidized specimen showed virtually no thickness loss due to corrosion, indicating excellent corrosion resistance in the laboratory corrosion environment for 100h.
机译:用实验室和现场腐蚀试验评估了表面改性T22钢作为废焚烧液中的过热器管的耐腐蚀性。用Ni-30At涂覆样品表面。百分比Cr-15at。通过不平衡 - 磁控管(UBM)溅射约10pm厚的百分比,然后在干燥实验室空气中以1000℃预氧化12h。通过在550℃的1000pPMHCl-50pPMSO_2-10%O_2-10%CO_2-10%H_2O-BAL中心点N_2的气体混合物中用合成灰涂覆来进行实验室腐蚀测试。在550℃下,预氧化试样几乎没有厚度损失由于腐蚀,表明实验室腐蚀环境中优异的耐腐蚀性为100h。

著录项