摘要

Craniotomy using a drill and saw frequently results in fragmentation of the skull plate. Lasers have the potential to remove the skull plate intact. TE CO_2 lasers operating at the peak absorption wavelength of bone (lambda=9.6 mum) and with pulse duration of 5-10 mus, approximately the thermal relaxation time in hard tissue, produced high ablation rates and minimal peripheral thermal damage. Both thick (2 mm) and thin (250 mum) bovine skull sample were perforated and the ablation rates calculated. Results were compared with Q-switched and free-running Er:YAG lasers (lambda=2.94 mum, tau_p=150 ns and 150 mus). The CO_2 laser perforated thick sections at ablation rates of 10-15 mum per pulse and fluences of approx 6 J/cm~2. There was no discernible thermal damage and no need for water irrigation during ablation. Pulse durations >=20 mus resulted in significant tissue charring which increased with the pulse duration. Although the Er:YAG laser produced ablation rates of approx 100 mum per pulse, fluences > 30 J/cm~2 were required to perforate thick samples, and thermal damage measured 25-40 mum. In summary, the novel 5-10 mus pulse length of the TE CO_2 laser is long enough to avoid a marked reduction in the ablation rate due to plasma formation and short enough to avoid peripheral thermal damage through thermal diffusion during the laser pulse. Further studies with the TE CO_2 laser are warranted for potential clinical application in craniotomy procedures.
机译:使用钻头的Craniotomy经常导致头骨板的碎片。激光有可能移除头骨板完整。 TE CO_2激光器在骨骼(Lambda = 9.6毫米)的峰值吸收波长下操作,脉冲持续时间为5-10亩,大约是硬组织中的热弛豫时间,产生高消融率和最小的外围热损坏。厚(2mm)和薄(250毫米)牛颅骨样品被穿孔,并计算烧蚀率。将结果与Q开关和自由运行ER进行比较:YAG激光器(Lambda = 2.94妈妈,Tau_p = 150 ns和150亩)。 CO_2激发厚切片以10-15毫米的烧蚀率,每次脉冲和大约6J / cm〜2的流量。没有可辨别的热损坏,并且在消融期间不需要水灌溉。脉冲持续时间> = 20毫秒导致显着的组织计量,随着脉冲持续时间而增加。虽然ER:YAG激光产生每脉冲约100毫米的消融率,但需要流量> 30J / cm〜2来穿孔厚的样品,并测量25-40毫米的热损伤。总之,TE CO_2激光器的新型5-10毫巴脉冲长度足够长,以避免由于等离子体形成而显着的消融率的降低,并且足够短,以避免通过激光脉冲期间的热扩散来避免外围热损坏。对TE CO_2激光进行进一步的研究,以进行Craniotmy程序的临床应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号