【24h】

A Compressor Failure That MOC May Not Have Caught!

机译:MOC可能没有捕获的压缩机失败!

获取原文

摘要

Reciprocating compressors were used to provide cooling for polymerization reactions at Goodyear's Beaumont, Texas, chemical plant. In November 1993, a refrigeration compressor failed catastrophically and resulted in a large propane release followed by a vapor cloud explosion that injured seven associates. The investigation became a complex evaluation and analysis of the process, procedures, machinery, materials, maintenance, and inspection activities. The investigation utilized two different metallurgical examination methods to assist in determining compressor part failure. Finite element analysis was used to analyze stress and predict failure location. The process, equipment, investigation details, and conclusions are presented. The persistence of the team through a difficult investigation resulted in many valuable lessons learned. One root cause was traced to a subtle change made to the compressor seventeen years earlier. Even with 20/20 hindsight, would your PHA team evaluating this MOC have predicted the failure?
机译:往复式压缩机用于在Goodyear的Beaumont,德克萨斯州化学厂提供聚合反应的冷却。 1993年11月,制冷压缩机失败了灾难性,导致大型丙烷释放,然后受到七个员工的蒸气云爆炸。调查成为对过程,程序,机械,材料,维护和检验活动的复杂评估和分析。调查利用两种不同的冶金检查方法来帮助确定压缩机部件故障。有限元分析用于分析应力并预测失效位置。提出了过程,设备,调查细节和结论。团队通过困难的调查持久性导致了许多有价值的经验教训。一个根本原因追溯到十七年前对压缩机进行的微妙变化。即使是20/20的后视,您的PHA团队是否会评估此MOC已预测失败?