The research on the definition and measurement approaches of reactive power considering the influence of harmonics has become popular. In this paper, according to reactive power defined by Budeanu, a novel method based on ANF (adaptive notch filter) for the digital measurement of the single-phase reactive power in the presence of harmonics is presented. Compared with the well-established techniques such as FFT, the proposed method offers higher degree of accuracy, simple algorithm and frequency-adaptivity. The structural simplicity of the method renders it suitable for both software and hardware implementations. Based on simulation studies, performance of the method is presented and its accuracy and immunity to the frequency variations are compared with a FFT-based method.
机译:考虑谐波影响的无功功率定义和测量方法研究变得流行。本文根据Budeanu定义的无功功率,提出了一种基于ANF(自适应陷波滤波器)的新方法,用于在存在谐波中的单相无功功率的数字测量。与FFT等良好技术相比,所提出的方法提供更高程度的准确性,简单的算法和频率适应性。方法的结构简单性使其适用于软件和硬件实现。基于仿真研究,提出了该方法的性能,并将其对频率变化的精度和免疫力与基于FFT的方法进行了比较。