摘要

Anti-islanding is an indispensable protecting function in grid-connected photovoltaic (PV) systems. As one of islanding detection methods, Active Frequency Drift with Positive Feedback (AFDPF) methods are widely used currently. Such methods, however, increase the grid current harmonies to a large extent. This paper proposes a modified AFDPF method which can effectively detect the islanding in due course through calculating the cross-correlation index to change the rate of frequency deviation whilst keeping the increment of total harmonic distortion (THD) of the grid current small enough during normal operating situation. The corresponding numerical simulation and experiment based on the anti-islanding test standard from IEEE Std. 929-2000 demonstrate that the proposed method has better performances than the conventional detection methods.
机译:反岛是网格连接光伏(PV)系统中不可或缺的保护功能。作为孤岛检测方法之一,目前广泛使用具有正反馈(AFDPF)方法的主动频率漂移。然而,这种方法在很大程度上增加了网格电流和谐。本文提出了一种改进的AFDPF方法,通过计算互相关指数来改变频率偏差速率的互相关指数,可以有效地检测岛屿,同时保持栅格电流的总谐波失真(THD)在正常操作中足够小。情况。基于IEEE STD的反岛试验标准的相应数值模拟与实验。 929-2000表明,所提出的方法具有比传统检测方法更好的性能。