Fixed point calibration method is normally used for noble metal thermocouples. Basic metal thermocouples, on the other hand, are usually calibrated by comparison. This happens because of their electromotive force (emf) instability in short time. This paper tries to enlighten this discussion presenting results which confirm that type N thermocouples have the best emf stability among base metal thermocouples. The calibration method, laboratory facilities, results, and uncertainty budget are reported in this paper. Only sheathed thermocouples having compacted mineral oxide insulation were calibrated in four fixed points: silver, aluminium, zinc, and tin. Annealing effects and emf reproducibility are presented along 100h in several calibrations.
机译:固定点校准方法通常用于贵金属热电偶。另一方面,基本金属热电偶通常通过比较校准。这发生由于它们在短时间内的电动势(EMF)不稳定。本文试图启发出该讨论呈现结果,该结果确认N型热电偶具有最佳的基础金属热电偶的EMF稳定性。本文报道了校准方法,实验室设施,结果和不确定性预算。只有四个固定点校准具有压实矿物氧化物绝缘的护套热电偶:银,铝,锌和锡。在几种校准中,退火效应和EMF再现性沿100h呈现。