In this paper, we present the ongoing process of the research and development of the Printed Circuit Heat Exchanger (PCHE) on Floating Storage Regasification Unit (FSRU). We performed a structural simulation work to find the optimal design of fluid channels on heat transfer plates, fabricated the heat transfer plates, and calculated the capacity of the PCHE using our analytical tool. In the simulation work, the plates having channels of 1 mm semicircular cross section were designed by varying the wall thickness between channels. At a temperature, 1373 K, compressing pressures were varied as 30, 85.7, and 500 bars. Based on the simulation results, we fabricated and bonded heat transfer plates using the diffusion bonding equipment which our department developed. Then, the sizing of PCHE was done with analytical calculation for the developing PCHE on FSRU.
机译:在本文中,我们在浮动储存remasification单元(FSRU)上展示了印刷电路热交换器(PCHE)的研究和开发的持续过程。我们进行了结构模拟工作,以找到传热板上的流体通道的最佳设计,制造了传热板,并使用我们的分析工具计算了PCHE的容量。在模拟工作中,通过在通道之间改变壁厚,设计了具有1mm半圆形横截面的通道的板。在温度下,1373k,压缩压力变化为30,85.7和500巴。基于仿真结果,我们使用我们部门开发的扩散粘合设备制造和粘合传热板。然后,通过对FSRU的显影PCHE进行分析计算来完成PCHE的尺寸。