首页> 外文会议>IEEE Technical Applications Conference and Workshops Northcon >Test results and initial operating experience for the BPA 500 kV thyristor controlled series capacitor design, operation, and fault test results
【24h】

Test results and initial operating experience for the BPA 500 kV thyristor controlled series capacitor design, operation, and fault test results

机译:测试结果和BPA 500 KV晶闸管控制系列电容器设计,操作和故障测试结果的初始操作经验

获取原文

摘要

A cooperative effort has resulted in the construction of the first 500 kV Thyristor Controlled Series Capacitor (TCSC). This device is installed on the Bonneville Power Administration (BPA) transmission system in the Northwestern United States. Project participants included BPA, the Electrical Power Research Institute (EPRI), General Electric Company (GE), and the Portland General Electric Company (PGE). The TCSC was commissioned in the fall of 1993, initiating an extended test and evaluation period. Evaluation tests included: harmonic performance, staged system faults, subsynchronous resonance (SSR) torsional mode damping, and system swing damping performance. Results of the system tests illustrate the TCSC's ability to improve power system operation. Upon completion of the evaluation tests, the TCSC was placed into commercial operation in January 1995. This initiated a one year trial operational period to evaluate the long term operation of the device.
机译:合作效果导致了第500 kV晶闸管控制系列电容器(TCSC)的构建。该设备安装在美国西北部的Bonneville Power Implation(BPA)传输系统上。项目参与者包括BPA,电力研究所(EPRI),通用电气公司(GE)和波特兰通用电气公司(PGE)。 TCSC于1993年秋季委托,启动了扩展测试和评估期。评估测试包括:谐波性能,分阶段系统故障,子同步谐振(SSR)扭转模式阻尼,以及系统摆动阻尼性能。系统测试的结果说明了TCSC改善电力系统操作的能力。在完成评估测试后,将于1995年1月汇入商业运营。这启动了一年的试验期限,以评估设备的长期运行。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号