In general, measurement error, including a precision error and a bias error, is defined as the difference between the true and measured values. Moreover, measurement error is also necessarily included in the temperature measurement using IR radiometer; however error estimation for IR radiometer has not been investigated yet. In the present study we discussed several primary factors on a measurement error and estimate a qualitative error pertaining to IR radiometer using the uncertainty analysis method based on ANSI/ASME PTC 19.1 - 1985. Detailed clarification of measurement error is important to develop a practical temperature measurement using IR radiometer. It was newly revealed from the uncertainty analysis utilized here that the measurement using IR radiometer is available in obtaining several radiative quantities. In addition, from a series of thermal visualization using IR radiometer, the relation between friction energy and a surface temperature is clarified to tribology behavior of the surface.
机译:通常,包括精度误差和偏置误差的测量误差被定义为真实和测量值之间的差异。此外,使用IR辐射计的温度测量也必须包括测量误差;然而,IR辐射计的误差估计尚未被调查。在本研究中,我们在测量误差上讨论了几个主要因素,并使用基于ANSI / ASME PTC 19.1-1955的不确定性分析方法估计与IR辐射计有关的定性误差。测量误差的详细澄清对于开发实际温度测量非常重要使用IR辐射计。从这里使用的不确定性分析新揭示了使用IR辐射计的测量可用于获得多种辐射数量。另外,通过使用IR辐射计的一系列热敏性化,摩擦能和表面温度之间的关系澄清到表面的摩擦学行为。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号