An optical test has been devised to test and qualify null correctors that are used for measuring highly aspheric primary mirrors. The technique employs a rotationally symmetric computer- generated hologram (CGH) that tests the null corrector directly by synthesizing a wavefront that would be returned by a perfect primary mirror. A description of the test and summary of the error analysis are given. The error analysis includes hologram errors from pattern distortion, substrate flatness, and etch depth variations. It also includes the effects of errors in the wavelength and data analysis errors. This resulting analysis shows $POM 78 ppm accuracy for measuring the conic constant of null correctors built for measuring 3.5 -m f/1.75 primary mirrors.
机译:已经设计了一种光学测试来测试和限定用于测量高度球面主镜的空校正器。该技术采用旋转对称的计算机生成的全息图(CGH),其通过合成由完美的主镜子返回的波前来直接测试空校正。给出了对误差分析的测试和概要的描述。误差分析包括来自图案失真,基板平整度和蚀刻深度变化的全息图误差。它还包括波长和数据分析误差中的错误的影响。此结果分析显示了$ POM 78 PPM精度,用于测量用于测量3.5-C / 1.75主镜的空校正的无效校正的圆锥常数。