Hybrid 3P4W DSTATCOM for three phase four wire distribution system

机译:混合3P4W DSTATCOM用于三相四个线配电系统

获取原文

摘要

For the improvement power quality in the three phase four wire distribution system; a star-delta transformer based dynamic static compensator (DSTATCOM) has been proposed. The proposed hybrid three phase four DSTATCOM (3P4W DSTATCOM) is comprising of AC power capacitor; three phase three wire dynamic static compensator (3P3W DSTATCOM); a star-delta transformer and a single phase neutral line compensator. A control scheme based on least mean square algorithm is used for reference current estimation. The star-delta transformer and single phase neutral line compensator are used to mitigate the neutral current. This hybrid approach reduces the rating of the semi-conductor switches of 3P4W DSTATCOM and improves the performance under different utility voltage conditions. To study performance of the proposed system extensive MATLAB/Simulink computer simulation is carried out.
机译:为三相四电线配电系统的提高电能质量;已经提出了基于Star-Delta变压器的动态静态补偿器(DSTATCCOM)。所提出的混合三相四个DSTATCOM(3P4W DSTATCOM)包括交流电容器;三相三电线动态静态补偿器(3P3W DSTATCOM);星三角形变压器和单相中性线补偿器。基于最小均方算法的控制方案用于参考电流估计。 Star-Delta变压器和单相中性线路补偿器用于减轻空档电流。这种混合方法减少了3P4W DSTATCOM的半导体开关的额定值,并在不同的公用电压条件下提高了性能。为了研究所提出的系统的性能,进行了广泛的MATLAB / SIMULINK计算机仿真。