首页> 外文会议>IEEE International Conference on Power Electronics, Intelligent Control and Energy Systems >Starting Performance of Doubly Fed Induction Machine Drive Serving to Pumped Storage Plants Subjected to Faults in Power and Control Circuits
【24h】

Starting Performance of Doubly Fed Induction Machine Drive Serving to Pumped Storage Plants Subjected to Faults in Power and Control Circuits

机译:双馈进料机驱动器的起始性能适用于泵送电源和控制电路故障的储存工厂

获取原文
获取外文期刊封面目录资料

摘要

Doubly Fed Induction Machine (DFIM) is preferred in pumping applications since it offers high efficiency and energy conservation at part load operation with a partial rating of power converters. In this machine; smooth starting is ensured by back-back voltage source power converter connected in rotor circuit. This paper summarizes the procedure for the smooth starting of DFIM with a selection of both converter rating and DC link voltage. In addition; this paper primarily presents the dynamic behavior during smooth starting of machine under converter and sensor faults where converter/sensors are considered as significance component in DFIM; also the survival of machine drive during starting period is evaluated under different fault conditions with the performance consideration of DC link voltage; grid current; controller settling time and speed fluctuations.
机译:在泵送应用中,双馈进料机(DFIM)是优选的,因为它在零件负载操作中提供了高效率和节能,具有功率转换器的部分额定值。在这台机器中;通过连接在转子电路中的背压电压源功率转换器确保光滑的启动。本文总结了DFIM的光滑起动,选择转换器额定值和直流链路电压。此外;本文主要介绍了在转换器和传感器故障下的平稳启动过程中的动态行为,其中转换器/传感器被认为是DFIM中的重要组件;此外,在不同的故障条件下,在起始时段期间的机器驱动的存活率随着DC链路电压的性能考虑;网格电流;控制器稳定时间和速度波动。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号