In air conditioning systems, the use of thermal energy storage coupled with heat pump is an efficient way for shifting electricity consumption from peak hours. This paper describes a hybrid dynamic model of an air-cooled heat pump coupled with a PCM (Phase Change Material) storage tank. Static models are used for the compressor and expansion valve of the heat pump. The heat exchangers and the storage models are based on a representation of the fluid flows by a cascade of Continuous Stirred Tank Reactors (CSTRs). The switching procedure between different model configurations associated to phase transitions within heat exchangers and PCM storage tank are mathematically performed by matrix operations. Numerical simulation with the Matlab software has been executed, which has shown qualitatively the relevance of the model.
机译:在空调系统中,使用与热泵相结合的热能存储是从高峰时段移位电力消耗的有效方式。本文介绍了一种与PCM(相变材料)储罐耦合的风冷热泵的混合动态模型。静态模型用于热泵的压缩机和膨胀阀。热交换器和存储模型基于流体流动的表示通过连续搅拌釜反应器(CSTR)的级联流动。与热交换器和PCM存储箱内的相位过渡相关联的不同模型配置之间的切换过程由矩阵操作进行数学地执行。已经执行了使用MATLAB软件的数值模拟,这表明了模型的相关性。