This study integrated building structure, heat flow mechanism and photovoltaic system to develop the ventilated building-integrated photovoltaic wall. A full-scale ventilated BIPV wall prototype was developed and investigated using field tests to explore its heat transfer characteristics. After considering building construction practices, this prototype was transformed into a curtain wall structure that complemented the design of the overall construction. The result shows that the ventilated BIPV wall with the flow channel can dissipate BIPV heat gain efficiently and enhance the power generation.
机译:本研究综合建筑结构,热流机构和光伏系统开发通风建筑集成光伏壁。使用现场测试开发并研究了全尺寸通风的BIPV墙原型,以探索其传热特性。在考虑建筑建筑实践之后,将该原型转变为窗帘墙体结构,该窗帘墙体结构补充了整体施工的设计。结果表明,具有流动通道的通风双光壁可以有效地散发BIPV热量,并增强发电。