首页> 外文会议>ICONE21 >TEMPERATURE FIELD ANALYSIS FOR FREEZING SEALING STRUCTURE OF SODIUM GATE VALVE IN CHINA EXPERIMENT FAST REACTOR (CEFR)
【24h】

TEMPERATURE FIELD ANALYSIS FOR FREEZING SEALING STRUCTURE OF SODIUM GATE VALVE IN CHINA EXPERIMENT FAST REACTOR (CEFR)

机译:中国实验快速反应堆钠闸阀冷冻密封结构的温度场分析(CEFR)

获取原文

摘要

In order to achieve the localization of the large-scale sodium gate valve in fast reactor nuclear power station, this paper use fluid software FLUEN, using two different methods, analysis temperature field of sodium gate valve freezing sealing structure of CEFR. The first method is to establish air model; the second method is to making use of experimental relation to calculate surface coefficient of heat transfer to simulate temperature field of freezing sealing structure of sodium gate valve in CEFR. Compared with measuring results on-site, simulation results of the first method have error within 10%. Therefore, it is feasible that simulating temperature field of freezing sealing structure with this method. That will promote structure design of freezing sealing of sodium gate valve for large fast rector power plant.
机译:为了实现快速反应堆核电站的大型钠闸阀的定位,本文使用流体软件Fluen,采用两种不同的方法,分析温度场钠闸阀冻结头部的密封结构。第一种方法是建立空气模型;第二种方法是利用实验关系来计算传热的表面系数,以模拟CEFR中钠闸阀的冷冻密封结构的温度场。与现场测量结果相比,第一种方法的仿真结果在10%内误差。因此,使用这种方法模拟冷冻密封结构的温度场是可行的。这将促进大型快速校长发电厂冰闸阀冷冻密封的结构设计。