On April 17, 2013, an explosion occurred at the West Fertilizer Company storage and distribution facility in West, Texas. The explosion at West Fertilizer resulted from an intense fire in the seed and storage area of the facility that led to the detonation of approximately 20-30 tons of ammonium nitrate stored inside a wooden receiving bin. The explosion occurred while emergency services personnel were responding to a fire at the facility and at least fifteen people were killed, more than 200 were injured, and numerous buildings were damaged or destroyed. The cause of the initial fire is still ongoing. This paper presents the initial evidence of our investigation into the cause and origin of the explosion event. In addition, the paper will also outline the current local, state and federal regulations regarding the storage and use of reactive chemicals such as ammonium nitrate.
机译:2013年4月17日,西部德克萨斯州西部肥料公司储存和配送设施发生了爆炸。西方肥料的爆炸由设施的种子和储存区域中的爆炸引起,导致储存大约20-30吨硝酸铵的爆炸,储存在木质接收箱内。发生爆炸,而紧急服务人员在设施的火灾中响应着火,至少十五人被杀死,超过200人受伤,众多建筑物受损或破坏。初始火灾的原因仍在继续。本文介绍了我们对爆炸事件的原因和起源调查的初步证据。此外,本文还将概述当前的本地,国家和联邦法规,了解硝酸铵等反应化学品的储存和使用。