摘要

Many point to point HVDC lines are already in operation in several countries. However, the development of multiterminal DC grids is slowed by the lack of efficient control and protection strategies that can be applied on such grids. This article deals with the protection aspect of those networks. Indeed, the resort to Voltage Source Converters (VSC) changes the constraints since the short circuit current can flow through the freewheel diodes in case of the event of a DC fault. This paper investigates a new protection algorithm suitable as main protection algorithm. It is based on the use of supplementary inductors placed at each end of the lines.
机译:许多点到点HVDC线路在几个国家已经运行。然而,通过缺乏可以在此类网格上应用的有效控制和保护策略,缺乏有效的控制和保护策略,速度的发展减慢了。本文涉及这些网络的保护方面。实际上,手段到电压源转换器(VSC)改变了约束,因为在发生直流故障的情况下,短路电流可以流过续流二极管。本文调查了一种适用于主要保护算法的新保护算法。它基于使用放置在线的每个端部的补充电感器。