首页> 外文会议>Annual ISA POWID symposium >Addressing Inadequate Upstream/Downstream Dimensions for DP Flow Measurement
【24h】

Addressing Inadequate Upstream/Downstream Dimensions for DP Flow Measurement

机译:解决DP流量测量的上游/下游尺寸不足

获取原文

摘要

Over the past several years, Bechtel has been challenging senior mechanical engineering students from the University of Colorado at Colorado Springs (UCCS) with real world problems in support of the Senior Design Program. During a recent challenge, the aspiring engineers were challenged with the question “When space is limited how can you measure flow using differential pressure measurement and how can you certify the installation for custody transfer.” In other words, what can be done if there isn’t enough physical space to meet code requirements? This paper outlines the structure of the Senior Design Project program at UCCS. In responding to this specific challenge, the student turned to CFD Modeling and with somewhat surprising results, present a solution that is realistic and verifiable. The paper shows the solution to the paper as the students progressed through the program to the end. The paper also discusses verification through testing in a laboratory to certify for custody transfer.
机译:在过去的几年里,Bechtel一直挑战科罗拉多州大学的高级机械工程学生,在科罗拉多斯普林斯(UCC),具有现实世界的问题,支持高级设计计划。在最近的挑战期间,有抱负的工程师的问题受到了问题的挑战“当空间有限时,如何使用差压测量测量流量,以及如何证明维护转移。”换句话说,如果没有足够的物理空间以满足代码要求,可以做些什么?本文概述了UCCS高级设计项目计划的结构。在回应这一特定挑战时,学生转向差价合约建模,并遇到了一些令人惊讶的结果,提出了一种现实和可核实的解决方案。本文显示了本文的解决方案,因为学生通过该计划进入结束。本文还讨论了通过在实验室中进行测试来证明保管转移的验证。