In recent years voltage unbalance and fault analysis in induction motor independently has been researched by engineers dealing with power quality issues. The exposure of the motor to unbalanced supply, combined with broken rotor bar fault significantly increases the temperature and reduces the efficiency and life of the motor. In this paper the effect of unbalance on broken rotor bar fault of the squirrel cage induction motor is analyzed. The performance of the induction motor is studied using symmetrical component analysis for the extracted stator current. The electromagnetic torque is analyzed, and is found to give sufficient information about the fault and the unbalance condition. The simulation of the proposed methodology is done using MATLAB SIMULINK.
机译:近年来,在处理电力质量问题的工程师,独立研究了感应电机的电压不平衡和故障分析。电机暴露于不平衡供应,与断开转子杆故障相结合显着提高了温度并降低了电动机的效率和寿命。本文分析了不平衡对鼠笼感应电动机断裂杆故障的影响。使用用于提取的定子电流的对称分量分析研究感应电动机的性能。分析电磁扭矩,并被发现提供有关故障和不平衡条件的充分信息。使用MATLAB Simulink完成所提出的方法的模拟。