Alloy 600 (A600) steam generator (SG) tubing has been shown to be susceptible to stress corrosion cracking (SCC). Alloy 800 (A800) was developed as a replacement, though it has shown susceptibility to corrosion under certain conditions. The properties of the passive oxide films on both alloys were extensively analyzed to determine why the performance of A800 is superior to that of A600. Surface analysis to determine oxide composition was performed using X-ray photoelectron spectroscopy (XPS) and Auger Electron spectroscopy (AES). Electrochemical measurements were made using anodic polarization and electrochemical impedance spectroscopy (EIS). The oxide films on A600 and A800 were shown to have different electrochemical and compositional properties.
机译:合金600(A600)蒸汽发生器(SG)管已被证明易于应力腐蚀裂纹(SCC)。合金800(A800)被开发为替代品,但它表明在某些条件下对腐蚀的敏感性。广泛分析了两种合金上的无源氧化膜的性质,以确定A800的性能优于A600的原因。使用X射线光电子能谱(XPS)和螺旋钻电子光谱(AES)进行氧化物组合物的表面分析。使用阳极偏振和电化学阻抗光谱(EIS)进行电化学测量。显示A600和A800上的氧化膜具有不同的电化学和组成特性。