首页> 外文会议>MICCAI 2012 >A Fast and Noise-Robust Method for Computation of Intravascular Pressure Difference Maps from 4D PC-MRI Data
【24h】

A Fast and Noise-Robust Method for Computation of Intravascular Pressure Difference Maps from 4D PC-MRI Data

机译:一种快速和噪声鲁棒方法,用于计算4D PC-MRI数据的血管内压差图

获取原文

摘要

Noninvasive blood flow measurements by 4D flow-sensitive MRI can be used to compute the intravascular distribution of blood pressure. In this work, we present an efficient algorithm for this task, based on the Navier-Stokes equations including zero-divergence condition for the velocity field. Its accuracy and robustness is investigated on two different CFD-based software phantoms. The method has been integrated into research software for analysis of clinical 4D flow measurements, and is tested on six patients with aortic coarctation. The pressure drop across the stenosis is quantified and coincides well with published results from a previously validated solution algorithm.
机译:4D流动敏感MRI的非血液流量测量可用于计算血压的血管内分布。在这项工作中,我们提出了一种基于Navier-Stokes方程的此任务的有效算法,包括速度场的零分配条件。在两种不同的基于CFD的软件幻影上调查了其准确性和鲁棒性。该方法已集成到研究软件中,用于分析临床4D流量测量,并在六个患有主动脉造环的患者上进行测试。通过先前验证的解决方案算法的公开结果,量化狭窄的压降并与已公开的结果相一致。

著录项