首页> 外文会议>International Universities' Power Engineering Conference >Advances on the Electromagnetic Field Distribution Analysis inside High Voltage Substations
【24h】

Advances on the Electromagnetic Field Distribution Analysis inside High Voltage Substations

机译:高压变电站内电磁场分布分析的研究进展

获取原文

摘要

This paper outlines the most recent developments regarding the electric field distribution analysis inside very high voltage substations. The study was performed in order to develop and validate a powerful computation tool able to determine and predict the substation zones where the occupational exposure limits exceeds the admissible values imposed by the legislation. The study cases proposed in the paper are taken from the Romanian national power grid but the conclusions and the mitigation ideas outlined can be directly extended to substations belonging to other national power grids. In the first part of the paper the principles and methods proposed by the authors for the electric field computation in the vicinity of the power devices composing a high voltage substation are outlined. The validation of the computation module implemented was done by comparisons with detailed experimental measurements results performed inside a new rehabilitated 400 kV substation. The evaluation of the results outlines a good agreement between the computed and measured electric field values inside the analyzed substation. This fact motivates the usage of the computation module developed in the design of the future high voltage substations in the light of fulfilling the actual regulations regarding the human exposure to power electric and magnetic fields. In the second part of the paper scenarios to reduce the field values inside the future designed or rehabilitated substations are proposed and examined. The field distributions together with comparison between the field values before and after the implementation of the field mitigation techniques proposed are presented and discussed. The final conclusions end the paper.
机译:本文概述了关于高压变电站内电场分布分析的最新发展。进行该研究以开发和验证能够确定和预测职业曝光限制超出立法施加的可允许值的变电站的变电站的功能。本文提出的研究案件取自罗马尼亚国家电网,但概述的结论和缓解思想可以直接扩展到属于其他国家电网的变电站。在本文的第一部分中,概述了作者提出的用于组成高压变电站的功率器件附近的电场计算的原理和方法。实现的计算模块的验证是通过比较来完成的,具有在新的恢复400 kV变电站内进行的详细实验测量结果。结果评估概述了分析的变电站内计算的和测量电场值之间的良好一致性。这一事实旨在鉴于满足关于人体暴露于电力电场和磁场的实际规定,实现计算模块在未来的高压变电站的设计中开发的计算模块。在纸张场景的第二部分中,提出并检查了未来设计或恢复变电站内的场值。呈现和讨论了所提出的现场缓解技术之前和之后的场值之间的比较。最后的结论结束了论文。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号