This work addresses the issues of actuator fault detection and isolation for diesel engines. We are particularly interested to diagnosis faults affecting the Exhaust Gas Recirculation (EGR) and the variable Nozzle Turbine (VNT) actuator valves. To accomplish this goal, a residual generator based on a nonlinear mean value model of the diesel engine is proposed using a bank of observer. Each residual on the proposed scheme is based on a nonlinear unknown input observer and designed to be insensitive to only one fault. By using this kind of scheme, the actuator faults can be easily isolated since only one residual goes to zero while the others do not. A decision algorithm based on multi-CUSUM is used. The performances of the proposed approach are shown through the application to a diesel engine model.
机译:这项工作解决了柴油发动机的执行器故障检测和隔离问题。我们特别感兴于影响废气再循环(EGR)和可变喷嘴涡轮(VNT)致动器阀的诊断故障。为了实现这一目标,使用一组观察者提出了一种基于柴油发动机的非线性平均值模型的剩余发电机。所提出的方案上的每个残差都基于非线性未知的输入观察者,并且设计为仅对一个故障不敏感。通过使用这种方案,可以容易地隔离执行器故障,因为只有一个剩余速度为零,而其他剩余物也没有。使用基于多CuSum的决策算法。通过应用于柴油发动机模型,示出了所提出的方法的性能。