摘要

Operational trends for the six-gyrotron electron cyclotron heating system on DIII-D are presented. Losses in the transmission lines were measured and values close to theoretical were attained for one of the lines with the existing components. Improved alignment and reduction of the number of miter bends in the lines will increase the power transmitted through the waveguide to the DIII-D tokamak.
机译:提出了DIII-D上的六陀螺电子回旋加热系统的操作趋势。测量传输线中的损耗,并对具有现有组件的一条线达到接近理论的值。改进的对准和减小线路中的斜切弯曲的数量将使通过波导传递到DIII-D Tokamak的功率。