Measurement Methodology for Tempomandibular Joint Displacement Based on Focus Mutual Information Alignment of CBCT Images

机译:基于CBCT图像焦点相互信息对齐的颞下颌关节位移测量方法

获取原文
获取外文期刊封面目录资料

摘要

Maxillofacial surgery can lead to displacement of the mandibular joint, bone resorption and finally articulatory dysfunctions. Bimaxillary surgical correction of a high angle absolute mandibular retrognathism case may provoke condy-lar resorption. An in vivo measurement method is developed to evaluate mandibular joint displacement aiming at correlating it with possible long-term clinical symptoms. For 6 patients two consecutive Cone Beam Computed Tomography (CBCT) images are obtained before and after functional craniofacial surgery. The images are superimposed using a fuzzy 3D alignment criterion: Focus Mutual Information (FMI), in which the operator only needs to indicate approximately the (anatomic) structure in the pre-image. Changes in the left mandibular joint are studied from the alignment of the images focussing on the left mandibular ra-mus. An analogous alingnment procedure is applied to the right mandibular ramus. The average age of the patients was 30 years, ranging from 16 to 48 years, 1 male and 5 female. The subtraction images reveal clear change in geometry in 7 of the 12 joints. The rotation in the horizontal plane ranges from -11.2° to 8,8°, with p. = -0.9°, and o = 4.9°, the rotation in the frontal plane ranges from -6.8° to 9.5°, with n = 0.0°, and a = 5.1°. The translational displacement of the caput with respect to the fossa ranges from 0.2mm to 3.1mm in the horizontal plane, with u = 1.0mm, and a = 0.9mm. Minimal distances lower than 1mm have been observed. The semi-automatic alignment and measurement method based on FMI allows for superimposition of 3D CBCT images and makes it possible to accurately measure distortion of the mandibular joint during or immediately after orthodontic surgery allowing for instantaneous corrections.
机译:颌面外科可以导致下颌关节,骨吸收和最终铰接性功能障碍的位移。 Bimaxillary手术校正高角度绝对下颌的回肠案可能会引发冷凝剂的吸收。开发了一种体内测量方法,以评估下颌关节位移,旨在将其与可能的长期临床症状相关。对于6名患者,在功能性颅面外科之前和之后获得了两个连续的锥形光束计算机断层扫描(CBCT)图像。使用模糊3D对准标准叠加图像:聚焦互信息(FMI),其中操作员仅需要指示预图像中的大致(解剖)结构。从聚焦在左颌骨Ra-MU上的图像的对准中研究了左下颌关节的变化。类似的孵化程序适用于右下颌骨。患者的平均年龄为30年,从16岁到48岁,1名男性和5名女性。减法图像揭示了12个关节中7中的几何形状的明显变化。水平平面的旋转范围从-11.2°到8,8°,p。 = -0.9°和o = 4.9°,正面平面的旋转范围从-6.8°到9.5°,n = 0.0°,A = 5.1°。水平平面中,调节件相对于窝的翻译位移在水平平面中为0.2mm至3.1mm,u = 1.0mm,= 0.9mm。已经观察到低于1mm的最小距离。基于FMI的半自动对准和测量方法允许叠加3D CBCT图像,并且可以在允许瞬时校正后或后立即测量下颌关节的变形。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号