Explosion risks resulting from the industrial handling of aqueous ammonia solutions are often not taken into account in risk assessments, especially for dilute solutions, although accidental explosions implying ammonia vapours are reported in the literature. In fact, ammonia solutions do not show any flash point, but are able to form an explosive atmosphere. In this study, explosivity characteristics of several ammonia solutions, more or less diluted, were determined in a 20 litre (0,71 Ft~3) sphere device. It appears that the explosion range of ammonia solutions depends on the temperature and on the ammonia concentration. The explosion severity is smaller than for pure ammonia because of the presence of water and it tends to decrease slightly with dilution. However the maximal explosion pressure is still above 3 bar (43,5 psig) with the 10 % solution. Hence, such aqueous solutions, even diluted, handled in enclosed spaces can generate hazardous explosions.
机译:氨水溶液产业处理产生的爆炸风险通常不会考虑风险评估,特别是对于稀释解决方案,尽管文献中报告了暗示氨蒸汽的意外爆炸。事实上,氨溶液没有显示任何闪点,但能够形成爆炸性的气氛。在该研究中,在20升(0,71ft〜3)球体装置中测定几种氨溶液的爆炸性特性,或多或少稀释。似乎氨溶液的爆炸范围取决于温度和氨浓度。由于存在水,爆炸严重程度小于纯氨,并且易于稀释略微降低。然而,最大爆炸压力仍然高于3巴(43,5psig),10%溶液。因此,在封闭的空间中处理的这种含水溶液甚至稀释,可以产生危险的爆炸。