Currently, centrifugal fan system has been used in ducted air-conditioning indoor unit, and this system has no enough advantage in heat transfer efficiency, noise control, air distribution and installation engineering. This paper adopts the CFD method to simulate the internal flow fields of ducted air-conditioning indoor unit and studies a new type flow duct of ducted air-conditioning indoor unit that took on character with cross-flow fan, air suction 6-bend heat exchanger, air intake from below etc. Compare to the same cooling capacity machine of centrifugal fan system, the new one reduced the indoor unit's sound pressure level 4~6dB(A), enhanced EER one class and reduced the whole size especially in width direction of machine that is just half size and easy installation. And the new machine was available for market competition because of the lower price.
机译:目前,离心式风扇系统已用于管道空调室内机,该系统在传热效率,噪声,空气分配和安装工程中没有足够的优势。本文采用CFD方法模拟了管道空调室内机的内部流量,研究了一种新型流量管道的管道空调室内机,带有横流风扇,空气吸入6弯换热器,从下面的进气等等。与离心式风扇系统相同的冷却能力机相比,新的一个缩小室内单位的声压级4〜6dB(a),增强eer一类,尤其是宽度方向降低了整体尺寸机器只有一半尺寸和安装方便。由于价格较低,新机器可用于市场竞争。