The rotor eccentricity of a large hydro-generatorcould cause a huge radial magnetic force, known as an unbalanced magnetic pull (UMP), exerting on the rotor. In this paper, Maxwell stress tensor (MST) method is used to compute the UMP based on the 2D finite element (FE) calculation, and the accuracy of UMP FE calculations is investigated. This paper presents a new method for the FE calculation of UMP due to rotor eccentricity in large hydro-generators. This method significantly overcomes difficulties of loading over thousand current sources for the UMP FE calculation of large hydro-generators with hundred stator slots operating under loads. In this paper, the UMP of a 240MW, 720-slot hydro-generator, for various degrees of rotor eccentricity, are calculated and compared for operations with no load, half rated, and rated load. The method proposed in this paper was successfully used to study the vibration of Three-Gorge generation units in China.
机译:大型水力发生器的转子偏心导致巨大的径向磁力,称为不平衡的磁力拉(UMP),施加在转子上。在本文中,Maxwell Regress Tensor(MST)方法用于基于2D有限元(FE)计算来计算UMP,并研究了UMP FE计算的准确性。本文由于大型水力发生器中的转子偏心,介绍了UMP的FE计算的新方法。该方法显着克服了在负载下运行的数百个定子槽的大型水力发生机UMP FE计算造成千流源的困难。本文采用了240MW,720槽水力发生器的UMP,用于各种转子偏心率,并比较无负载,半额定和额定负载的操作。本文提出的方法已成功地用于研究中国三峡生成单位的振动。