Imaging of venous valves with photoacoustics

机译:具有光声学的静脉阀的成像

获取原文

摘要

We report results of a feasibility study regarding the question whether or not venous valves can be imaged using photoacoustics, and how they will appear in the images. First an in vitro study was made on tissue phantoms consisting of blood filled rubber tubes with discontinuities in the inner tube wall. We also have studied superficial veins on the ventral side of the wrist. For excitation, an Nd:YAG laser at 1064 nm was used. Detection of acoustic signals was performed with a PVdF sensor consisting of two concentric rings. Measurements were performed on valves which where first localized by palpation. The phantom studies showed that irregular structures of the tube walls could clearly be identified from the photoacoustic images. Furthermore, in a photoacoustic image of a vein at the dorsal side of the wrist, the presence of a valve could be identified from a region of increased signal intensity within the vessel lumen.
机译:我们报告了关于可以使用光声学成像的问题的可行性研究的结果,以及如何在图像中出现。首先,在组织幽灵上制造了一种体外研究,这些植物由内管壁中的不连续性组成的血液填充的橡胶管。我们还研究了手腕腹侧的表面静脉。为了激发,使用1064nm的Nd:YAG激光。用由两个同心环组成的PVDF传感器进行声学信号的检测。测量在阀门上进行测量,其中首先通过触诊定位。幻影研究表明,管壁的不规则结构可以清楚地从光声图像中识别。此外,在手腕背侧的静脉的光声图像中,可以从血管内部内的信号强度的增加的区域识别阀的存在。