THE SYNERGISTIC / ANTAGONISTIC EFFECT OF WATER TREATMENT CHEMICALS ON CORROSION INHIBITION OF CARBON STEEL IN THE WATER INJECTION SYSTEM OF WEST KUWAIT OIL FIELDS

机译:水处理化学品对西科威特油田注水系统碳钢腐蚀抑制的协同/拮抗作用

获取原文

摘要

This study evaluated the corrosion inhibition of three corrosion inhibitors and particularly the influence of their complementary biocide and scale inhibitors to treat aquifer and effluent brines used in water injection systems of West Kuwait oil fields. The Rotating Cylinder Electrode (RCE) test was first used to measure the performance of the chemicals under shear conditions. The best two performing inhibitors were then tested in an autoclave to observe their performance under actual system pressure and temperature. In the RCE test the biocide and the scale inhibitors from each supplier decreased the effectiveness of the corresponding corrosion inhibitor packages for the two brines. However, a fatty amines corrosion inhibitor and a quaternary amines corrosion inhibitor and their corresponding biocide/scale inhibitor packages showed better protection and therefore were selected for the autoclave tests. The autoclave test results indicated that both of the selected corrosion inhibitor/scale inhibitor/biocide packages performed well at higher pressure and acid gas exposures. The fatty amine corrosion inhibitor and its associated biocide/scale inhibitor provided 95% and 90% protection in the aquifer and effluent waters, respectively; whereas the quaternary amines corrosion inhibitor and its associated biocide/scale inhibitor provided 96.5% and 94.5% protection in the aquifer and effluent waters, respectively. It is suggested that under the autoclave conditions, which more closely resemble field conditions, the biocide and scale inhibitors do not reduce the inhibitory activity of the corrosion inhibitor in the two waters as much as under RCE conditions. Based on these results both systems are considered viable candidates for further trials examining scale inhibition, biocide activity and field trials in these water systems.
机译:该研究评估了三种腐蚀抑制剂的腐蚀抑制,特别是其互补杀生物剂和水垢抑制剂对西科威特油田供水系统中使用的含水层和流出物盐水的影响。首先使用旋转圆筒电极(RCE)测试来测量剪切条件下化学品的性能。然后在高压釜中测试最好的两种表现抑制剂,以观察其在实际系统压力和温度下的性能。在RCE测试中,来自每个供应商的杀生物剂和刻度抑制剂降低了两个盐水相应腐蚀抑制剂包装的有效性。然而,脂肪胺腐蚀抑制剂和季胺腐蚀抑制剂及其相应的杀生物剂/水垢抑制剂封装显示出更好的保护,因此选择用于高压釜试验。高压釜测试结果表明,两种选定的腐蚀抑制剂/水垢抑制剂/杀生物剂封装在较高的压力和酸性气体曝光时良好地进行。脂肪胺腐蚀抑制剂及其相关的杀生物剂/水垢抑制剂分别在含水层和污水水域中提供95%和90%的保护;然而,季胺腐蚀抑制剂及其相关的杀生物剂/水垢抑制剂分别在含水层和流出水域中提供96.5%和94.5%的保护。建议在高压灭菌条件下,其更紧密地类似于现场条件,杀生物剂和水垢抑制剂在rCE条件下尽可能地降低两种水中腐蚀抑制剂的抑制活性。基于这些结果,两种系统被认为是可行的候选者,用于进一步试验检查这些水系统中的抑制作用,杀生物剂活性和现场试验。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号