首页> 外文会议>IAS Annual Meeting >An Improved Stator Flux Estimation for a Variable Structure Direct Torque Controlled IPM Synchronous Motor Drive Using a Sliding Observer
【24h】

An Improved Stator Flux Estimation for a Variable Structure Direct Torque Controlled IPM Synchronous Motor Drive Using a Sliding Observer

机译:使用滑动观测器的可变结构直接扭矩控制IPM同步电动机驱动的改进的定子磁通估计

获取原文

摘要

This paper presents improvements of the stator flux estimation for a variable structure direct torque controlled (DTC) interior permanent magnet (IPM) synchronous motor drive. A variable structure observer is proposed to estimate the stator flux linkage based on the IPM motor current model. Compared to open-loop estimator, the observer improves the performance of the IPM motor drive. The experimental results demonstrate that the proposed observer is able to deliver more accurate estimation than open-loop estimator both in the steady state and during transients. Performance of encoder-less operation at very low speed is enhanced significantly.
机译:本文介绍了可变结构直接控制(DTC)内部永磁(IPM)同步电动机驱动器的定子通量估计的改进。提出了一种基于IPM电机电流模型来估计定子通量连杆的可变结构观察者。与开环估计器相比,观察者提高了IPM电机驱动器的性能。实验结果表明,所提出的观察者能够在稳定状态和瞬态期间提供比开环估计更准确的估计。更低速度的编码器操作的性能显着提高。