首页> 外文会议>International Zurich Symposium on Electromagnetic Compatibility >Measurement and Analysis of Electromagnetic Disturbances in +-500kV Converter Stations
【24h】

Measurement and Analysis of Electromagnetic Disturbances in +-500kV Converter Stations

机译:+ -500kV转换站电磁干扰的测量与分析

获取原文

摘要

In order to evaluate the electromagnetic environment in HVDC converter station, measurements were performed in two +-500kV converter stations. Both the stable and transient disturbances were recorded and analyzed. The measurement layout is introduced and some results of the measurement and analysis are given in this paper. These results can be used as the references of EMC design of the secondary equipments in HVDC converter station.
机译:为了评估HVDC转换器站中的电磁环境,在两个+ -500kV转换器站中进行测量。记录和分析稳定和瞬态扰动。引入了测量布局,本文给出了测量和分析的一些结果。这些结果可用作HVDC转换器站中辅助设备EMC设计的参考。