The Effect of Using Real Gas Absolute Viscosity and Isentropic Exponent on Orifice Flow Measurement: Proposed Adoption of REFPROP 8.0 as a Standard for the Natural Gas Industry

机译:使用真实气体绝对粘度和等熵指数对孔口流量测量的影响:提出了REFPROP 8.0作为天然气工业标准的

获取原文

摘要

Constant values for isentropic exponent and absolute viscosity are commonly used for the calculation of gas flow rates through differential producing flowmeters. Errors in flow measurement due to the use of constants for thermodynamic and transport properties are bias errors. Bias errors in natural gas orifice flow measurement due to incorrect isentropic exponent values can exceed 0.15percent. When the adiabatic expansion factor is used to calculate natural gas flow rates the bias errors due to the use of a constant isentropic exponent can exceed 2percent. Bias errors in natural gas flow measurement due to incorrect absolute viscosity values can approach 0.2percent for natural gas. REFPROP 8.0 is recommended as a source of accurate thermodynamic and transport property values. REFPROP 8.0 can be used as a source of live values for use with flow computers or it can be used to select more appropriate constant values to minimize bias errors.
机译:常态指数和绝对粘度的恒定值通常用于通过差动产生流量计计算气流速率。由于使用用于热力学和传输属性的常数而导致的流量测量误差是偏置错误。由于不正确的等熵指数值,天然气孔流量测量中的偏差误差可能超过0.15平方。当绝热膨胀因子用于计算天然气流速时,由于使用恒定的等熵指数而导致的偏差误差可能超过2percent。由于绝对粘度值不正确,天然气流量测量中的偏差误差可以接近天然气的0.2。 REFPROP 8.0建议作为准确的热力学和传输属性值的源。 REFPROP 8.0可以用作与流量计算机一起使用的实时值的源,或者可用于选择更合适的常量值以最小化偏置错误。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号