This paper introduces a new method, named radiation periodic integration measurement (RPIM), to improve the imaging speed and quality in the scan radiography without the interference of circuit RC time constant. However, the integral period may sometimes be different from the sampling period in practice, especially when the scan velocity exceeds a certain value, which will result in image distortion. In order to solve this problem, this paper also establishes an equivalent mathematical model to emulate the RPIM, and develop the corresponding image reconstruction theory and algorithm to restore the distorted image. All those are applied in Tsinghua Cobalt-60 train cargo online inspection system, and the scan velocity increases greatly up to 45km/h. ^g>radiation measurement; radiography; image reconstruction
机译:本文介绍了一种新方法,命名辐射周期集成测量(RPIM),以提高扫描放射线照相中的成像速度和质量,而不会干扰电路RC时间常数。 然而,积分周期有时可以与实践中的采样周期不同,特别是当扫描速度超过一定值时,这将导致图像失真。 为了解决这个问题,本文还建立了仿真RPIM的等效数学模型,并开发了相应的图像重建理论和算法来恢复失真图像。 所有这些都适用于清华钴-60火车货物在线检查系统,扫描速度大大增加至45公里/小时。 ^ g>辐射测量; 造影; 影像重建