LEACHATE AND LANDFILL GAS EXTRACTION FROM AN UNLINED LANDFILL

机译:渗滤液和垃圾填埋气体从无衬里垃圾填埋场提取

获取原文
获取外文期刊封面目录资料

摘要

In order to deal with high leachate levels within the Sioux Falls Regional Sanitary Landfill, R. W. Beck worked with the City of Sioux Falls to design a dual-phase leachate and landfill gas extraction system in the unlined 100-acre portion of the City of Sioux Falls Landfill, located approximately 6 miles west of Sioux Falls, South Dakota. This $1.1 million dollar system consists of 19 (of approximately 100 eventual) vertical leachate and landfill gas extraction wells, connecting laterals and headers, leachate drains, and lift stations to dewater the Landfill. Historically, high leachate levels (up to 60 feet above the base of the landfill) needed to be drawn down in order to satisfy regulatory closure requirements and allow landfill gas collection and recovery. R. W. Beck designed a unique extraction system utilizing a single well casing and drain system combining both gas and liquids recovery. Pneumatic leachate pumps were installed in each well, discharging leachate to the perimeter landfill gas header pipe, where the leachate and condensate are separated out at six different lift stations. When designing this system, R. W. Beck evaluated several options for removing the leachate from the landfill. These options included: 1. Horizontal wells vs. vertical wells 2. Well design for collection of both leachate and landfill gas 3. Electric pumps vs. pneumatic pumps 4. Optimum spacing and location of vertical wells 5. Collection and perimeter manifold piping orientation The system has been operational since October, 2005. The lessons learned during the design, construction and operation of the system will be beneficial to a large number of landfill professionals and managers who have leachate management issues. This project has also spurred a landfill gas utilization project due to the amount of landfill gas collected by the newly constructed system.
机译:为了应对苏福尔斯地区卫生填埋内高渗滤液水平,RW贝克与市苏福尔斯的曾在市苏福尔斯的无衬里100英亩部分来设计一个双相沥滤液和填埋气提取系统垃圾填埋场,位于南达科他州Sioux Falls以西约6英里。这款110万美元的系统由19(大约100个最终)的垂直渗滤液和垃圾填埋气体提取井组成,连接侧板和标头,渗滤液排水管和提升站填埋场。历史上,需要抽取高渗滤液(高达60英尺的垃圾填埋场底部),以便满足监管闭合要求,并允许垃圾填埋气体收集和恢复。 R. W. Beck设计了一种独特的提取系统,利用单一的套筒壳体和排水系统,所述气体和液体恢复。在每个孔中安装了气动渗滤液泵,将浸出液排放到周边垃圾填埋气体管道,其中渗滤液和冷凝物在六个不同的提升站中分离出来。在设计该系统时,R. W. Beck评估了从垃圾填埋场去除渗滤液的几种选择。这些包括选项:1。水平井与垂直井2.井设计两个沥滤液和填埋气3.电泵与气动收集泵4.竖直井5.收集的和周界歧管管道取向最佳间距和位置系统自2005年10月以来一直在运作。在制度的设计,建设和运营期间汲取的经验教训将有利于大量垃圾填埋场专业人士和有渗滤液管理问题的经理。由于新建系统收集的垃圾填埋气量,该项目还促进了垃圾填埋气利用项目。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号