PRA results are sensitive to uncertainties in setting threshold for equipment-damage criteria. Equipment-damage criteria under elevated ambient temperature are important in Salem PRA. A number of postulated fire scenarios cause loss of temperature control (HVAC) in fire PRA made the criteria more important. An analysis of equipment operability under elevated ambient temperature was performed. It determined that equipment modelled in PRA could function after the ambient temperature exceeded environmental qualification (EQ). For some areas and scenarios, equipment could operate for the mission time. For the rest, equipment could operate a much longer time window thus providing better opportunity for operator actions. However, due to accelerated thermal aging, equipment failure rates could be significantly worse. Failure rates under the elevated temperature are largely equipment specific. Options to obtain new failure rates were explored and discussed. Engineering approach was selected. Using the engineering approach, new failure rates corresponding to elevated ambient temperature were derived. Fire PRA was re-quantified using new equipment-damage criteria. New CDF and LERF values were significantly smaller. For instance, for 4KV switchgear room, the CDF and LERF values were reduced by a factor of 13 and 16 respectively.
机译:PRA结果对设定设备损坏标准的设定阈值敏感。环境温度下的设备损坏标准在塞勒姆PRA中很重要。一些假设的火灾情景导致火灾中的温度控制(HVAC)丧失,使标准更为重要。进行了在升高的环境温度下的设备可操作性分析。它确定在PRA中建模的设备可以在环境温度超过环境资格(EQ)之后起作用。对于某些领域和场景,设备可以为任务时间运营。对于其余的,设备可以操作更长的时间窗口,从而为操作员操作提供更好的机会。但是,由于热老化加速,设备故障率可能会显着差。高温下的故障率主要是特定的设备。探讨并讨论获得新失败利率的选项。选择了工程方法。使用工程方法,推导出对应于升高的环境温度的新失效率。使用新的设备损坏标准重新定量火灾PRA。新的CDF和LERF值明显较小。例如,对于4kV开关设备,CDF和LERF值分别减少了13和16的因子。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号