In this study, the CO_2 expansion inside the two-phase ejector was modelled. To simulate the two-phase flow inside the device, two models were applied, namely homogeneous equilibrium model (HEM) and homogeneous relaxation model (HRM). The two-phase flow models were implemented on the effective computational tool called ejectorPL. This script guarantee the fully automated and systematic computations for various ejector shapes and operating conditions. Originally, only the HEM approach was implemented in ejectorPL. However the accuracy analysis of the HEM showed lack of model fidelity for the operating conditions far from the carbon dioxide critical point. The simulated motive nozzle mass flow rate showed very good agreement with the experimental values for the operating regimes, while for the points far from the critical point the motive nozzle mass flow rate was underestimated. To improve the ejectorPL performance, the HRM was applied to simulate the refrigerant flow inside the ejector. Then, the accuracy of that approach was evaluated. To assess the accuracy of the model, the computed motive nozzle and suction nozzle mass flow rates were compared with the experimental data. The operating conditions used for that analysis were typical for the supermarket refrigeration system. The results of the HRM accuracy analysis and the difference between the HEM and HRM accuracy for the specific operating regimes will be presented in 12th IIR Gustav Lorentzen Natural Working Fluids Conference.
机译:在这项研究中,模拟了两相喷射器内的CO_2膨胀。为了模拟器件内的两相流,应用了两种型号,即均匀的平衡模型(下摆)和均匀的松弛模型(HRM)。两相流模型是在称为EjectorPL的有效计算工具上实现的。此脚本保证了各种喷射器形状和操作条件的全自动和系统计算。最初,只有下摆方法在Ejectorpl中实施。然而,下摆的精度分析显示出远离二氧化碳临界点的操作条件的模型保真度。模拟动力喷嘴质量流量与操作制度的实验值表示非常良好,而对于远离临界点的点,显着的光点被低估了动力喷嘴质量流量。为了提高EJECTORPL性能,应用HRM以模拟喷射器内的制冷剂流动。然后,评估该方法的准确性。为了评估模型的准确性,将计算的动力喷嘴和吸嘴浓缩率与实验数据进行比较。用于该分析的操作条件对于超市制冷系统典型。 HRM精度分析的结果以及特定操作制度的下摆和HRM精度的差异将在第12届IIR Gustav Lorentzen Natural Working Fills会议上提出。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号